Aller au contenu principal
C&I Energy Storage System HVC7 / HVC6

KV-C · 2 modèles

C&I Energy Storage System HVC7 / HVC6

HIGH VOLTAGE LITHIUM ION BATTERY ENERGY STORAGE SYSTEM · HVC7 (50kW-100kWh) — HVC6 (30kW-50kWh)

Points forts

  • High Power & Capacity
  • Efficient Performance
  • Scalable Solution
  • Advanced Protection
  • Easy Installation
  • Smart Monitoring
Télécharger le PDF

OEM disponible — boîtier, marquage et emballage peuvent porter votre marque.

Caractéristiques

SpecificationsHVC7 (50kW-100kWh)HVC6 (30kW-50kWh)
Battery System Parameters
Battery Module Type51.2V
Battery Module Number74
Battery Module Dimension442*750*230mm
Battery System Voltage358.4V204.8V
Battery Capacity280Ah
Normal Energy100kWh50kWh
Battery Max Charge Current160A100A
Battery Max Discharge Current160A100A
Charge Voltage386.4V220.8V
Cut-off Voltage313.6V179.2V
System Parameters
Communication PortEMS: RS485, Battery: CAN or RS485
DIDODI*2 DO*2
Efficiency97%
Module Weight35kg*235kg
Dimension440*560*183mm
IP RateIP20
Work Temperature Range-30~60°C
Humidity5~95% RH
CoolingFAN
Inverter CertificateCE, IEC62019, IEC62477, IEC61000, EN50549
Inverter Parameters (50kW / 30kW)
Max Battery Voltage850V
Min Battery Voltage160V160V
Normal Voltage Range320V~850V320V~850V
Max Charge/Discharge Current160A100A
PV Parameter
Max Power30kW*219.2kW+19.2kW
Max PV Voltage850V
PV Start Voltage250V
MPPT Voltage Range200V~830V
Max PV Current(25A+25A)*232A+32A
On Grid
Normal Power25kVA*218kVA
Normal Current36.2A*226A
AC voltage400V/230V
AC voltage range-20%~15%
Frequency Range50Hz/47Hz~52Hz, 60Hz/57Hz~62Hz
Power Factor-0.8~0.8
Off Grid
Normal Power25kVA*218kVA
Max Out Power27.5kVA*221kVA
Normal Current36.2A*226A
Max Output Current40A*230A
AC Voltage400V/230V
Output Voltage Harmonics<3% (resistive load)
Degree Of Unbalance100%
Frequency Range50/60HZ
Overload(39.8A<I load≤45A/100s, 45A<I load≤54A/100ms)*228.6A<I load≤32.5A/100s, 32.5A<I load≤39A/100ms
Cabinet
CoolingAir conditioner
System Weight≈1430kg≈915kg
DimensionApprox 1000*1450*2100mmApprox 800*1450*2100mm
Inverter InstallationBuilt-in Cabinet

* If the ambient temperature is too high or too low, performance will be limited.

* Under specific test conditions.

Spécification indicative. Confirmée par écrit au stade du devis. Les fiches techniques sont publiées en anglais.

Certificats

  • UN38.3 — Lithium battery transport test

    UN38.3

    Lithium battery transport test

    CMC Testing · CMC241023142 · 2024-11-28

    Rapport complet sur demande

  • MSDS — Material safety data sheet

    MSDS

    Material safety data sheet

    CMC Testing · CMC241023141M02 · 2026-01-01

    Rapport complet sur demande

  • Safe Transport — Sea transport of goods report

    Safe Transport

    Sea transport of goods report

    CMC Testing · CMC241023141H02 · 2026-01-01

    Rapport complet sur demande

  • EMC — EN IEC 61000-6-2 / 6-4 / 3-2 / 3-3

    EMC

    EN IEC 61000-6-2 / 6-4 / 3-2 / 3-3

    CTG Testing · CTG2603272284E_SR66AB · 2026-03-27

    Rapport complet sur demande

Produits associés

Tous les produits

Dites-nous ce que vous voulez construire.

Envoyez une spécification, une nomenclature ou simplement une description du projet. Vous recevrez une vraie réponse technique — pas une brochure.