KV-X · 9 modèles
Low-Frequency Split-Phase Solar Inverter
120VAC/230VAC 1-12KW
Points forts
- Low Frequency Split Phase
- UPS
- PV Storage System
- Built-in MPPT
- Smart APP — RJ11/RJ45 RS232/485 for Option
- AC Four-Level Charging Mode
- Smart LED/LCD Setting
- Pure Sine Wave Output
OEM disponible — boîtier, marquage et emballage peuvent porter votre marque.
Caractéristiques
| Model | 1KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW |
|---|---|---|---|---|---|---|---|---|---|
| AC INPUT | |||||||||
| Nominal Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W | 8000W | 10000W | 12000W |
| Input Voltage Waveform | Pure Sine Wave (Same as Input/Bypass Mode) | ||||||||
| Nominal Input Voltage | 120VAC (LV models) | 230VAC (HV models) | |||||||
| Low Line Disconnect | 85Vac±4% (Normal) or 80Vac±4% (Wide) | 184Vac±4% (Normal) or 155Vac±4% (Wide) | |||||||
| Low Line Re-connect | 95Vac±4% (Normal) or 85Vac±4% (Wide) | 194Vac±4% (Normal) or 165Vac±4% (Wide) | |||||||
| High Line Disconnect | 135Vac±4% (Normal) or 142Vac±4% (Wide) | 253Vac±4% (Normal) or 270Vac±4% (Wide) | |||||||
| High Line Re-connect | 125Vac±4% (Normal) or 135Vac±4% (Wide) | 243Vac±4% (Normal) or 255Vac±4% (Wide) | |||||||
| Max AC Input Voltage | Max 150Vac | Max 270Vac | |||||||
| Frequency | 50Hz: 41–54Hz / 60Hz: 51–64Hz | ||||||||
| AC OUTPUT | |||||||||
| Output Voltage Waveform | Sine Wave | ||||||||
| Power Factor | 0.9–1.0 | ||||||||
| Nominal Output Voltage (V) | 120Vac±10%rms | 120V/230Vac±10%rms | |||||||
| Nominal Output Frequency (Hz) | 60Hz±0.3Hz / 50Hz±0.3Hz | ||||||||
| AC CHARGER | |||||||||
| Nominal Charge Current | 28A/50A/70A/90A (4-stage adjustable charging current, according to the model) | ||||||||
| Charge Current Regulation | ±25%A dc | ||||||||
| Over Charge Protection | Bat.V≥15.5VDC for 12V battery; Bat.V≥31.0VDC for 24V battery; Bat.V≥62.0VDC for 48V battery; beeps 0.5s every 1s & fault after 60s | ||||||||
| Algorithm | Three stage: Boost CC (constant current) → Boost CV (constant voltage) → Float (constant voltage) | ||||||||
| SOLAR CHARGER | |||||||||
| Rated Charge Current | 40A (1–5KW models) · 60A (6–12KW models) | ||||||||
| Max. PV Open Circuit Array Voltage | 40Vdc for 12V; 55Vdc for 24V; 110Vdc for 48V | ||||||||
| Charger Mode | MPPT | ||||||||
| PV Low Voltage Re-connect | PV > Bat.V+3V | ||||||||
| PV Low Voltage Disconnect | PV = Bat.V | ||||||||
| Efficiency | >97% | ||||||||
| EFFICIENCY | |||||||||
| Efficiency (Battery Mode) | ≥85% | ||||||||
| Efficiency (Line Mode) | >96% | ||||||||
| BATTERY VOLTAGE | |||||||||
| Nominal DC Input Voltage | 12/24/48VDC | ||||||||
| Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC; 21VDC±0.6VDC for 24VDC; 42VDC±1.2VDC for 48VDC | ||||||||
| Low DC Input Shut-Down | 10VDC±0.3VDC for 12VDC; 20VDC±0.6VDC for 24VDC; 40VDC±1.2VDC for 48VDC | ||||||||
| High DC Input Alarm & Fault | 16VDC±0.3VDC for 12VDC; 32VDC±0.6VDC for 24VDC; 64VDC±1.2VDC for 48VDC | ||||||||
| Transfer Time | 15ms (max) | ||||||||
| SYSTEM PARAMETER | |||||||||
| Over-load Protection | 110%<load<150%, beeps 0.5s every 1s, fault after 60s off the output; Load>150%, beeps 0.5s every 1s, fault after 20s | ||||||||
| Output Short Circuit Protection | Current limit (Fault after 10s) | ||||||||
| Surge Rating (VA) | 1:3 (VA) | ||||||||
| Power Saver | Load<25W (Enabled on P/S auto setting of remote control) | ||||||||
| Protections | Low battery, over charging, over load, over temp | ||||||||
| Indicators | LED + LCD Display | ||||||||
| GENERAL SPECIFICATIONS | |||||||||
| Operating Temperature Range | 0°C to 40°C | ||||||||
| Storage Temperature | -15°C ~ 60°C | ||||||||
| Operation Humidity | 5% to 95% (non-condensing) | ||||||||
| Audible Noise | 60dB max | ||||||||
| Cooling | Forced air, variable speed fan | ||||||||
| Dimensions (L×W×H mm) | 425×376×200 (1–3KW) · 560×420×235 (4–6KW) · 655×480×240 (8–12KW) | ||||||||
| Weight (KG) | 19 | 22 | 29 | 33 | 36 | 39 | 58 | 61 | 63 |
* If the ambient temperature is too high or too low, performance will be limited.
* Under specific test conditions.
Spécification indicative. Confirmée par écrit au stade du devis. Les fiches techniques sont publiées en anglais.
Certificats

UN38.3
Lithium battery transport test
CMC Testing · CMC241023142 · 2024-11-28
Rapport complet sur demande

MSDS
Material safety data sheet
CMC Testing · CMC241023141M02 · 2026-01-01
Rapport complet sur demande

Safe Transport
Sea transport of goods report
CMC Testing · CMC241023141H02 · 2026-01-01
Rapport complet sur demande

EMC
EN IEC 61000-6-2 / 6-4 / 3-2 / 3-3
CTG Testing · CTG2603272284E_SR66AB · 2026-03-27
Rapport complet sur demande
Produits associés
Tous les produitsDites-nous ce que vous voulez construire.
Envoyez une spécification, une nomenclature ou simplement une description du projet. Vous recevrez une vraie réponse technique — pas une brochure.