KV-X · 4 samfura
Low-Voltage Hybrid Inverter, Three-Phase
3-PHASE HYBRID
Amsa cikin ranar aiki ɗayaTuntuɓe mu
Siffofi
- 48V Low Voltage Battery
- Built-in Transformer for Safety Isolation
- Supports AC Coupling to Improve Solar System Efficiency
- Direct Support for Diesel Generator Power Without External Converter
- Max Charge and Discharge Current 240A
- Support to Set Up 6 Time Periods of Charge/Discharge
- Up to 10 Units Parallel During On/Off-grid Operation
- Supports Multiple Battery Parallel
Akwai OEM — akwati, alama da marufi na iya ɗaukar alamarku.
Bayanan fasaha
| Model | 6K | 8K | 10K | 12K |
|---|---|---|---|---|
| PV STRING INPUT | ||||
| Max. DC Input Power (W) | 7800 | 10400 | 13000 | 15600 |
| Rated PV Input Voltage (V) | 550 (160-800) | |||
| Start-up Voltage (V) | 160 | |||
| MPPT Voltage Range (V) | 200-650 | |||
| Full Load MPPT Voltage Range (V) | 350-650 | |||
| No. of MPP Trackers / Max. DC Input Current (A) | 13+13 | 13+13 | 26+13 | 26+13 |
| Max. DC Short Circuit Current (A) | 17+17 | 17+17 | 34+17 | 34+17 |
| No. of MPPT Trackers | 2 | |||
| No. of Strings Per MPPT Tracker | 2+1 | |||
| AC INPUT/OUTPUT DATA | ||||
| Rated AC Output and UPS Power (W) | 6000 | 8000 | 10000 | 12000 |
| Max. AC Output Power (W) | 6600 | 8800 | 11000 | 13200 |
| Peak Power (off grid) | 2 times of rated power, 10 S | |||
| AC Input/Output Rated Current (A) | 9.1/8.7 | 12.1/11.6 | 15.2/14.5 | 18.2/17.4 |
| Max. AC Input/Output Current (A) | 10/9.6 | 13.4/12.8 | 16.7/15.9 | 20/19.1 |
| Max. Three-phase Unbalanced Output Current (A) | 13.6/13 | 18.2/17.4 | 22.7/21.7 | 27.3/26.1 |
| Max. Output Short Circuit Current (A) | 75 | |||
| Max. Continuous AC Passthrough (A) | 45 | |||
| Power Factor | 0.8 leading ~ 0.8 lagging | |||
| Output Frequency and Voltage | 50/60Hz; 220/380Vac, 230/400Vac (Three Phase) | |||
| Grid Type | Three Phase Four Wire | |||
| Total Harmonic Distortion (THD) | <3% | |||
| DC Current Injection | <0.5%In | |||
| BATTERY | ||||
| Battery Type | Lead-acid or Lithium-ion | |||
| Battery Voltage Range (V) | 40-60 | |||
| Max. Charging Current (A) | 120 | 160 | 200 | 240 |
| Max. Discharging Current (A) | 120 | 160 | 200 | 240 |
| Charging Curve | 3 Stages/Equalization | |||
| External Temperature Sensor | Yes | |||
| Charging Strategy for Li-ion Battery | Self-adaption to BMS | |||
| EFFICIENCY | ||||
| Max. Efficiency | 97.6% | |||
| Euro Efficiency | 97.0% | |||
| MPPT Efficiency | 99.0% | |||
| CERTIFICATIONS AND STANDARDS | ||||
| Grid Regulation | IEC61727/62116/EN50549-1 | |||
| Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4; IEC/EN 62109-1; IEC/EN 62109-2 | |||
| GENERAL DATA | ||||
| Operating Temperature Range (°C) | -40 ~ +60°C, >45°C Derating | |||
| Cooling | Smart cooling | |||
| Noise (dB) | <50 dB | |||
| Communication with BMS | RS485/CAN | |||
| Monitoring Mode | WiFi/APP | |||
| Cabinet Size (mm) | 446(W)×576(H)×255D (Excluding connectors and brackets) | |||
| Weight (kg) | 37.5 | |||
| Warranty / Protection Degree | 5 Years (10 Years Optional) / IP65 | |||
Ja tebur ɗin don ganin kowane samfuri
* If the ambient temperature is too high or too low, performance will be limited.
* Under specific test conditions.
Bayanin fasaha na ƙiyasi. Ana tabbatarwa a rubuce lokacin ba da farashi. Ana wallafa takardun bayanai da Turanci.
Takardun shaida

UN38.3
Lithium battery transport test
CMC Testing · CMC241023142 · 2024-11-28
Cikakken rahoto idan an nema

MSDS
Material safety data sheet
CMC Testing · CMC241023141M02 · 2026-01-01
Cikakken rahoto idan an nema

Safe Transport
Sea transport of goods report
CMC Testing · CMC241023141H02 · 2026-01-01
Cikakken rahoto idan an nema

EMC
EN IEC 61000-6-2 / 6-4 / 3-2 / 3-3
CTG Testing · CTG2603272284E_SR66AB · 2026-03-27
Cikakken rahoto idan an nema
Kayayyaki masu alaƙa
Duk kayayyakiGaya mana abin da kuke son ginawa.
Aiko da bayanin fasaha, jerin kayan aiki, ko bayanin aikin kawai. Za ku sami amsar fasaha ta gaske — ba ƙasida ba.
Low-Voltage Hybrid Inverter, Three-Phase
Amsa cikin ranar aiki ɗaya